Flotation cell is widely used for separating non-ferrous metal, black metal, noble metal, non-metal mineral, raw body and materials of chemical industry, which are subject to coarse separation, swept separation, fine separation and flotation, so the useful ore are reclaimed.
1. Specifications of XJ Mechanical Agitating Flotation Cell With Auto Air Suction
Model Effective Volume
m3
Capacity
m3/min
Diameter of Impeller
mm
Revolution of Impeller
r/min
Motor Power 
(kw)
Weight of  
1 Cell
kg
Remarks
For 
agitating
 For 
paddle
XJ-1 0.13 0.05~0.16 200 600 1.5 0.55 320 It also be called as
“A”or “XJK”
,with Auto
su-ction 
ability for 
air and
pulp
XJ-2 0.23 0.12~0.28 250 504 3 0.55 390
XJ-3 0.35 0.18~0.4 300 483 3 0.75 430
XJ-6 0.62 0.3~0.9 350 400 3 1.1 860
XJ-11 1.1 0.6~1.6 500 330 5.5 1.1 1635
XJ-28 2.8 1.5~3.5 600 280 11 1.1 2430
XJ-58 5.8 3~7 750 240 22 1.5 3633

2. Specifications of XJQ Mechanical Agitating Flotation Cell With Auto Air Suction

Model Effective Volume
m3
Capacity
m3/min
Diameter of Impeller
mm
Revolution of Impeller
r/min
Motor Power 
(kw)
Weight of  4 Cells
kg
Remarks
For 
agitating
 For 
paddle
XJQ-4 4 2~5 400 290,315 11 1.1 6150/2
Cell
Suck air 
and slurry 
automatically
.
XJQ-8 8 4.2~10 560 205,225 22 1.1 9170/2
Cell
XJQ-16 16 8~20 700 170,180 30 1.5 16702/2
Cell
XJQ-28 28 14~35 760 166,185 55 1.5  

3.Specifications of XJB Foltation Cell

Model Effective Volume
m3
Capacity
m3/min
Diameter 
of
 Impeller
mm
Revolution 
of Impeller
r/min
Motor Power
(kw)
Weight of  4 Cells
kg
Remarks
For 
agitating
 For 
paddle
XJB-10 Sucking tank 1 1.5~1.7 400 440 5.5 1.5 5344 (1) Suck air and 
slurry automatically ,
 and locate
horizontally 
without foam
pump.
(2) Dindicates 
toscrapeout foam 
from single side.
Flotation tank 1 1.5~1.7 410 410 4 0.8 5344
XJB-10D  Sucking tank 1 1.5~1.7 400 440 5.5 1.5 5479
 Flotation tank 1 1.5~1.7 410 410 4 0.8 5479
XJB-20  Sucking tank 2 1.5~4 450 360 13 1.1 9071
 Flotation tank 2 1.5~4 540 360 10 1.1 9071
XJB-20D  Sucking tank 2 1.5~4 450 360 13 1.1 9320
 Flotation tank 2 1.5~4 540 360 10 1.1 9320
XJB-40  Sucking tank 4 2~4 700 280 17    
 Flotation tank 4 2~4 510 280 17    

4.Specifications of SF Mechanical Agitating Flotation Cell With Auto Air Suction

Model Effective Volume
m3
Capacity
m3/min
Diameter 
of Impeller
mm
Revolution 
of Impeller
r/min
Motor Power 
(kw)
Weight of  2 Cells
kg
Remarks
For 
agitating
For 
paddle
SF-0.37 0.37 0.2~0.4 300 352-442 1.5 0.55 936 Horizontally 
arranged
without foam pump
SF -0.7 0.7 0.3~1.0 350 336-384 3 1.1 1882
SF -1.2 1.2 0.6~1.6 450 312 5.5 1.1 2745
SF -2.0 2 0.5~2 560 312 5.5 1.1 4232
SF -2.8 2.8 1.5~3.5 550 268 11 1.5 4240
SF -4.0 4 2~4 650 235 15 1.5 5165
SF -8.0 8 4.0~8.0 760 191 30 1.5 8258
SF -10 10 5.0~10 760 191 30 1.5 8972
SF -16 16 5.0~16 850 180 45 1.5 14830
SF -20 20 5~20 760 191 30×2 1.5 19656

5. Specifications of JJF Mechanical Agitating Flotation Cell With Auto Air Suction

Model Effective Volume
m3
Capacity
m3/min
Diameter 
of
 Impeller
mm
Revolution 
of
 Impeller
r/min
Motor Power 
(kw)
Weight of 1 Cell
kg
Remarks
For 
agitating
For 
paddle
JJF-1.2 1.2 0.6~1.6 500 312 5.5 1.5 1320
Auto air suction,
to be arran-ged with gradient,and may 
be combined with model SF .
JJF-2 2 0.5~2.0 550 230 7.5 1.5 1419
JJF-2.8 2.8 1.5~3.5 590 268 11 1.5 2050
JJF-4 4 2~4 410 305 11 1.5 2303
JJF-5 5 2~6 410 305 11 1.5 2416
JJF-8 8 4~8 540 233 22 1.5 4500
JJF-10 10 5~10 540 233 22 1.5 4820
JJF-20 20 5~20 700 180 37 1.5 8500

6. Specifications of XJB Flotation Cell

Model Effective
 Volume
m3
Capacity
m3/min
Diameter 
of
 Impeller
mm
Revolution of Impeller
r/min
Motor Power 
(kw)
Weight of 1
Cell
kg
Remarks
For 
agitating
 For 
paddle
XJB-10 Sucking 1 1.5~1.7 400 440 5.5 1.5 5344 Suck air and slurry 
automatically , and locate 
horizontally
without foampump.
Dindicates to scrape
out foam from single
side.
Flotation 1 1.5~1.7 410 410 4 0.8 5344
XJB-10D Sucking tank 1 1.5~1.7 400 440 5.5 1.5 5479
Flotation tank 1 1.5~1.7 410 410 4 0.8 5479
XJB-20 Sucking  tank 2 1.5~4 450 360 13 1.1 9071
Flotation tank 2 1.5~4 540 360 10 1.1 9071
XJB-20D Sucking  tank 2 1.5~4 450 360 13 1.1 9320
Flotation tank 2 1.5~4 540 360 10 1.1 9320
XJB-40 Sucking tank 4 2~4 700 280 17    
Flotation  tank 4 2~4 510 280 17    

7. Specifications of XCF Mechanical Agitating Flotation Cell

Model Effective
Volume
m3
Capacity 
m3/min
Diameter 
of
Impeller
m
Revolution 
of
Impeller
r/mi
Air
 pressure 
of blower 
kpa
Max.air 
flow
m3/m2.
min
 Motor power Weight of Cell  
kg
Remarks
For agitating
kw
For Paddle
kw
XCF-1 1 0.2~1 400 358 ≥12.6 2 5.5 1.1 1154 It is aerated,and
the pulp is
automatically
pumped.
It is horizontally
arranged
without
foam pump
XCF-2 2 0.4~2 410 247 ≥14.7 2 7.5 1.1 1419
XCF-3 3 0.6~3 540 266 ≥19.8 2 11 1.5 2259
XCF-4 4 1.2~4 620 225 ≥19.8 2 15 1.5 2669
XCF-8 8 3~8 720 185 ≥21.6 2 22 1.5 3968
XCF-16 16 4~16 860 160 ≥25.5 2 37 1.5 6928
XCF-24 24 4~24 950 153 ≥30.4 2 37 1.5 10819
XCF-38 38 10~38 1050 138 ≥34.3 2 75 1.5 17790
XCF-40 40 10~40 1050 138 ≥34.3 2 75 1.5 18790
XCF-50 50 10~40 1200 125 ≥34.3 2 90 1.5 22000

8. Specifications of KYF Mechanical Agitating Flotation Cell

Model Effective
Volume
m3
Capacity 
m3/min
Diameter 
of
Impeller
m
Revolution 
of
Impeller
r/mi
Air pressure
of blower 
kpa
Max.air 
flow
m3/m2.
min
 Motor power Weight 
of Cell  
kg
Remarks
For 
agitating
kw
For Paddle
kw
KYF-1 1 0.2~1 340 281 ≥12.6 2 4 1.1 826 It needs
 blowing
air, and the
Pulpis auto
atically
pumped.
It should be
arranged with
gradient,
matchi-ng with
model XCF
KYF-1.2 1.2 0.2~1.2 410 247 ≥12.8 2 7.5 1.1 1410
KYF-2 2 0.4~2 410 247 ≥14.7 2 7.5 1.1 1419
KYF-3 3 0.6~3 480 219 ≥19.8 2 7.5 1.5 1885
KYF-4 4 1.2~4 550 200 ≥19.8 2 11 1.5 2206
KYF-8 8 3~8 630 175 ≥21.6 2 15 1.5 3857
KYF-16 16 4~16 740 160 ≥25.5 2 30 1.5 7545
KYF-24 24 4~24 800 150 ≥30.4 2 30 1.5 9820
KYF-38 38 10~38 880 138 ≥34.3 2 55 1.5 16097
KYF-40 40 10~40 950 135 ≥34.3 2 55 1.5 17097
KYF-50 50 10~40 1030 128 ≥34.3 2 75 1.5 22000

9. Specifications of BS-K Mechanical Agitating Flotation Cell

Model Effective 
 Volume
m3
Capacity 
m3/min
Diameter 
of 
Impeller
m
Revolution 
of
  Impeller
r/mi
Air 
pressure 
of
 blower 
kpa
Max.air 
flow
m3/m2.
min
 Motor power Weight 
of
 Cell  
kg
Remarks
For agitating
kw
For Paddle
kw
BS-K2.2 2.2 0.5~3 420 260 ≥15 2~3 5.5 0.75 1750 It should be arranged
with gradient
BS-K4 4 0.5~4 500 212 ≥15 3~6 7.5 1.1 2568
BS-K6 6 1~6 650 197 ≥27 4~10 18.5 1.1 3760
BS-K8 8 1~8 650 190 ≥20 4~10 15 1.1 6463
BS-K16 16 2~15 750 160,170 ≥27 6~15 30 1.1 9231
BS-K24 24 7~20 830 154,159 ≥29 8~-18 37 1.1 11000
BS-K38 38 10~30 910 141 ≥34 10~20 45 1.1 12677

10. Specifications of BSF Flotation Cell

Model Effective 
 Volume
m3
Capacity 
m3/min
Diameter 
of
 Impeller
m
Revolution 
of
  Impeller
r/mi
Air pressure of
 blower 
kpa
Max.air 
flow
m3/m2.
min
 Motor power Weight 
of Cell  
kg
Remarks
For agitating
kw
For Paddle
kw
BSF-2.2 2.2 0.5~3 420 260 ≥15 2~3 5.5 1.1 1750 It should be arranged
with gradient
BSF-4 4 0.5~4 500 230,220 ≥17 3~6 7.5 1.1 2568
BSF-6 6 1~6 650 197 ≥21 4~10 18.5 1.1 3760
BSF-8 8 1~8 650 180,190 ≥27 4~10 15 1.1 6463
BSF-16 16 2~15 750 160,170 ≥27 6~15 30 1.1 9231
BSF-24 24 7~20 830 154,159 ≥29 8~-18 37 1.1 10800
BSF-38 38 10~30 910 141 ≥34 10~20 45 1.1 12677

11.Specifications of JYF Flotation Cell

Model Effective
Volume
m3
Capacity 
m3/min
Diameter 
of
Impeller
m
Revolution 
of
Impeller
r/mi
Air 
pressure
of blower 
kpa
Max.air
flow
m3/m2.
min
 Motor power Weight 
of 
Cell  
kg
Remarks
For agitating
kw
For Paddle
kw
JYF-1 1 0.2~1 400 358 ≥12.6 2 5.5 1.1 1154 It is aerated,andthe pulp is
automatically
pumped.
It is horizontally
arranged without
foam pump
JYF-2 2 0.4~2 460 331 ≥14.7 2 7.5 1.1 1659
JYF-3 3 0.6~3 540 266 ≥19.8 2 11 1.1 2259
JYF-4 4 1.2~4 620 225 ≥19.8 2 15 1.1 2669
JYF-8 8 3~8 720 199.8 ≥21.6 2 22 1.5 3868
1~8 650 190 ≥21 2 15 1.5 3854
JYF-16 16 4~16 740 160 ≥25.5 2 30/37 1.5 6520
JYF-24 24 4~24 950 153 ≥30.4 2 37 1.5 8000
JYF-38 38 10~38 ≥34.3 2 45 1.5 11000

12.Specifications of GF Flotation Cell

Model Effective  Volume
m3
Capacity 
m3/min
Diameter 
of Impeller
m
Revolution of 
Impeller
r/mi
 Motor power Weight of Cell  
kg
Remarks
For agitating
kw
For Paddle
kw
GF-1.1 1.1 0.2~0.5 400 345 5.5 1.1   Horizontally arranged 
without foam pump
GF-2.0 2 0.3~1.0 490 293.9 7.5 1.5  
GF-3.0 3 0.5~1.5 570 268 11 1.5  

 

 

 

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待

Products Center

Related products

I want to make an inquiry
Key words
I want to make an inquiry
Key words
I want to make an inquiry
Key words