Flotation cells

产品名称

Flotation cells

没有此类产品
OVERVIEW

The products are divided into 9 main models.All models make up 70 kinds of products. Model XJ,also named model A or XJK, is a kind of traditional flotation machine which is capable of air and pulp suction. Model XJQ has the following features. (1) Dummy bottom is adopted, making the recycling capacity of the recycling cylinder is 2.5 times of the tank. (2) The stator is a cylingder in structure with its inner wall being vertically ribbed,and slots are placed, leading to better cutting effect to the slurry. (3) Due to low immerging depth of the rotator, low turning speed of the impeller, and wide space between the impeller and stator, wearing is low and power consumption greatly reduced. (4) It is spontaneously aerated. New structure of impeller is employed in model SF, which is backwards inclined double impellers equipped with honeycomb duct and dummy bottom.Therefore,the slurry in the tank will cycle upward and downward in a fixed flow manner, which is helpful to the suspension of those coarse particles. Air and slurry are naturally suked without foam pump. Model JJF has a moderate agitating strength, the solid particles being well suspended without settlement and no need for cleaning-up when stooped.The liquid surface is kept stable and it has higher flotation recovery. Due to the impeller has a shallow immerging depth and low periphery speed, It consumes less power and its wearable parts have longer serice life featuring easy maintenance. Dummy bottom and honeycomb duct are furnished. This machine has auto aeration ability. Flotation set of models SF and JJF works in a manner that model SF is taken as the suction function cell utilizing its auto suction ability, while model JJF works as a direct flow cell. Whole set may be installed horizontal and needs no foam pump. Model XJB floatation cell forms enforced aeration agitating machine set of skew wheel, boss and current regulating arc. Its reatures are as follows: (1)skew bar wheel is composed of disk and 12 pieces of cone-bar strip cast together in casting iron, and it can be lined with gum to prolong the service life. (2) Bar tsrip and bar wheel  bend backward 45° in the opposite direction and extent outward a cone apex angle with 15° from top to bottom, therefore its agitation is strong, the settlement of sand on the bottom of tank can be protected. (3) Due to low immerging depth of the bar wheel, the starting is easy during stopped condition and this is advantageous to increasing the aeration capacity and saving on energy consumption. (4) It is able to suck slurry and air automatically without foam pump. Impeller of model BF flotation cell is composed of the dosed double section cones and it can produce strong slurry cycle downward. Its features are as follows: (1) The capacity of air suction is large, the power  consumption is low. (2) Every tank has three functions of air suction, slurry suction and flotation simultaneously being unique in flotation return circuit without need for any supplementary equipment, the circuit change is convenievt for horizontal location. (3) The slurry cycle is rational, the settlement of coarse sand can be reduced into full play. (4) The regulation is convenient to equip auto and electro-controlling arangements for slurry level. Modeld XCF and KYF are enforced aeration flotation machine. It has a smaller diameter of impeller, thus lower peripheral speed, saving 30%~50% of power. Because an air distributor is equipped in the tank, air is evenly dispersed. The impeller acts as a centrifugal pump, so as to make the solid particles suspending. The tank is made as U type, reducing sand settlement to the least. Due to reasonable design of the impeller structure and the impeller space, impeller wearing is even, so, the service life of the impeller and stator are extended. Model KYF is unable to spontaneously suck slurry, while has low power consumption.Incontrast, model XCF has the ability to automatically suck slurry, and may be allocated horizontally without need for foam pump,but consumes more power than model KYF. Therefore, model XCF and model KYF ree combined into a set,i.e., XCF as the sucking tank, and KYF as the direct tank. The combined set can be arranged horizontally without foam pump either. Model BS-K is a kind of deep tank flotation machine with aeration. Again,the impeller plays roles of agitating slurry, cycling slurry, cycling slurry and distributing air. There fore, the wearable parts suffer less wearing. It requires less power than the other models. This machine has no ability to pump slurry, thus bench arrangement is necessary, and foam pump is needed. Impeller of (1)XJ型自 Specificationgs of XJ mechanical agitating flotation cell with arto air suction

Model m3Effective Volume Capacity m3/min mm Diameter of  impeller r/min Revolution of impeller (kw) Motor Power kg Weight of cells Remarks
For agitating For paddle
XJ-1 0.13 0.05~0.16 200 600 1.5 0.55 320 It also be called as “A” or “XJK”,with auto su- ction ability for air and pulp
XJ-2 0.23 0.12~0.28 250 504 3 0.55 390
XJ-3 0.35 0.18~0.4 300 483 3 0.75 430
XJ-6 0.62 0.3~0.9 350 400 3 1.1 860
XJ-11 1.1 0.6~1.6 500 330 5.5 1.1 1635
XJ-28 2.8 1.5~3.5 600 280 11 1.1 2430
XJ-58 5.8 3~7 750 240 22 1.5 3633

Specifications of XJQ mechanical agitating flotation cell with auto air suction

Model m3Effective Volume Capacity m3/min mm Diameter of  impeller r/min Revolution of impeller (kw) Motor Power kg Weight of 2 cells Remarks
For agitating For paddle
XJQ-4 4 2~5 400 290,315 11 1.1 6150/2 Suck air and slurry automatically .
XJQ-8 8 4.2~10 560 205,225 22 1.1 9170/2
XJQ-16 16 8~20 700 170,180 30 1.5 16702/2
XJQ-28 28 14~35 760 166,185 55 1.5  

Specifications of flotation cell

Model m3Effective Volume mm Inner dimensions L×W×H Impeller Air flow sucked m3/m2.min Motor Capacity m3/min Weight of   Single cell kg
mm Diameter m/s Periphery Speed Model kw Power
BF-0.15 0.15 550×550×600 200 6.0 0.9~1.05 Y90L-6 1.1 0.06~0.16 270
BF-0.25 0.25 650×600×700 250 6.0 0.9~1.05 Y100L-6 1.5 0.12~0.28 370
BF-0.37 0.37 740×740×750 295 7.2 0.9~1.05 Y90L-6 1.5 0.2~0.4 470
BF-0.65 0.65 850×950×900 300 7.35 0.9~1.10 Y132S-6 3.0 0.3~0.7 932
BF-1.2 1.20 1050×1150×1100 450 7.02 0.9~1.10 Y132M1-6 Y132M2-6 4.0 5.5 0.6~1.2 1370
BF-2.0 2.0 1400×1450×1120 500 7.5 0.9~1.10 Y160M-6 7.5 1.0~2.0 1750
BF-2.8 2.8 1650×1650×1150 550 8.06 0.9~1.10 Y180L-8 11 1.4~3.0 2130
BF-4.0 4.0 1900×2000×1200 650 8.0 0.9~1.10 Y200L-8 15 2.0~4.0 2585
BF-6.0 6.0 2200×2350×1300 700 7.5 0.9~1.10 Y225S-8 18.5 3.0~6.0 3300
BF-8.0 8.0 2250×2850×1400 760 7.5 0.9~1.10 Y225M-8 22 4.0~8.0 4130
BF-10 10 2250×2850×1700 760 7.52 0.9~1.10 Y225M-8 22 5.0~10 4990
BF-16 16 2850×3800×1700 850 8.7 0.9~1.10 Y280S-8 Y280M-8 37 45 8.0~16 7600
BF-20 20 2850×3800×2000 850 8.7 0.9~1.10 Y280S-8 Y280M-8 37 45 10~20 8670
BF-24 24 3150×4150×2000 920 8.7 0.9~1.10 Y280M-8 45 12~24 8970

Specifications of SF mechanical agitating flotation cell with auto air suction

Model m3 Effective Volume Capacity m3/min mm Diameter of  impeller r/min Revolution of impeller (kw) Motor Power 2槽重量 kg Weight of  2 cells Remarks
For agitating For paddle
SF-0.37 0.37 0.2~0.4 300 352-442 1.5 0.55 936 自吸空气,自吸矿浆 水平配置,不需泡沫泵 Horizontally arranged without foam pump
SF -0.7 0.7 0.3~1.0 350 336-384 3 1.1 1882
SF -1.2 1.2 0.6~1.6 450 312 5.5 1.1 2745
SF -2.0 2.0 0.5~2 560 312 5.5 1.1 4232
SF -2.8 2.8 1.5~3.5 550 268 11 1.5 4240
SF -4.0 4.0 2~4 650 235 15 1.5 5165
SF -8.0 8.0 4.0~8.0 760 191 30 1.5 8258
SF -10 10 5.0~10 760 191 30 1.5 8972
SF -16 16 5.0~16 850 180 45 1.5 14830
SF -20 20 5~20 760 191 30×2 1.5 19656

Specifications of JJF mechanical agitating flotation cell with auto air suction

Model m3Effective Volume Capacity m3/min mm Diameter of  impeller r/min Revolution of impeller (kw) Motor power kg Weight of cell Remarks
For agitating For paddle
JJF-1.2 1.2 0.6~1.6 500 312 5.5 1.5 1320 Auto air suction,to be arran- ged with gradient,and may be combined with model SF .
JJF-2 2 0.5~2.0 550 230 7.5 1.5 1419
JJF-2.8 2.8 1.5~3.5 590 268 11 1.5 2050
JJF-4 4 2~4 410 305 11 1.5 2303
JJF-5 5 2~6 410 305 11 1.5 2416
JJF-8 8 4~8 540 233 22 1.5 4500
JJF-10 10 5~10 540 233 22 1.5 4820
JJF-20 20 5~20 700 180 37 1.5 8500

Specifications of model XJB flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of impeller r/min Revolution of impeller (kw) Motor Power 4kg Weight of 4 cells Remarks
For agitating For paddle
XJB-10 Sucking tank 1 1.5~1.7 400 440 5.5 1.5 5344 (1)   Suck air and slurry automatically , and locate horizontally without foam pump. (2)   Dindicates to scrape out foam from single side.
Flotation tank 1 1.5~1.7 410 410 4.0 0.8 5344
XJB-10D Sucking tank 1 1.5~1.7 400 440 5.5 1.5 5479
Flotation tank 1 1.5~1.7 410 410 4.0 0.8 5479
XJB-20 Sucking tank 2 1.5~4 450 360 13 1.1 9071
Flotation tank 2 1.5~4 540 360 10 1.1 9071
XJB-20D Sucking tank 2 1.5~4 450 360 13 1.1 9320
Flotation tank 2 1.5~4 540 360 10 1.1 9320
XJB-40 Sucking tank 4 2~4 700 280 17    
Flotation tank 4 2~4 510 280 17    

Specifications of XCF mechanical agitating flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of Impeller r/min Revolution of impeller Air pressure of blower  kpa Max.air flow m3/m2.min Motor power Weight of cell  kg Remarks
kw For agitating kw For paddle
XCF-1 1 0.2~1 400 358 ≥12.6 2 5.5 1.1 1154 It is aerated,and the pulp is automatically pumped. It is horizontally arranged without foam pump
XCF-2 2 0.4~2 410 247 ≥14.7 2 7.5 1.1 1419
XCF-3 3 0.6~3 540 266 ≥19.8 2 11 1.5 2259
XCF-4 4 1.2~4 620 225 ≥19.8 2 15 1.5 2669
XCF-8 8 3~8 720 185 ≥21.6 2 22 1.5 3968
XCF-16 16 4~16 860 160 ≥25.5 2 37 1.5 6928
XCF-24 24 4~24 950 153 ≥30.4 2 37 1.5 10819
XCF-38 38 10~38 1050 138 ≥34.3 2 75 1.5 17790
XCF-40 40 10~40 1050 138 ≥34.3 2 75 1.5 18790
XCF-50 50 10~40 1200 125 ≥34.3 2 90 1.5 22000

Specifications of KYF mechanical agitating flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of Impeller r/min Revolution of impeller Air pressure of blower  kpa Max.air flow m3/m2.min Motor power Weight of cell  kg Remarks
kw For agitating kw For paddle
KYF-1 1 0.2~1 340 281 ≥12.6 2 4 1.1 826 It needs blowing air, and the Pulp is auto atically pumped. It should be arranged with gradient,matchi- ng with model XCF
KYF-1.2 1.2 0.2~1.2 410 247 ≥12.8 2 7.5 1.1 1410
KYF-2 2 0.4~2 410 247 ≥14.7 2 7.5 1.1 1419
KYF-3 3 0.6~3 480 219 ≥19.8 2 7.5 1.5 1885
KYF-4 4 1.2~4 550 200 ≥19.8 2 11 1.5 2206
KYF-8 8 3~8 630 175 ≥21.6 2 15 1.5 3857
KYF-16 16 4~16 740 160 ≥25.5 2 30 1.5 7545
KYF-24 24 4~24 800 150 ≥30.4 2 30 1.5 9820
KYF-38 38 10~38 880 138 ≥34.3 2 55 1.5 16097
KYF-40 40 10~40 950 135 ≥34.3 2 55 1.5 17097  
KYF-50 50 10~40 1030 128 ≥34.3 2 75 1.5 22000  

Specifications of BS-K mechanical agitating flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of Impeller r/min Revolution of impeller Air pressure of blower  kpa Max.air flow m3/m2.min Motor power kg Weight of cell Remarks
kw For agitating kw For paddle
BS-K2.2 2.2 0.5~3 420 260 ≥15 2~3 5.5 0.75 1750 It should be arranged with gradient
BS-K4 4 0.5~4 500 212 ≥15 3~6 7.5 1.1 2568
BS-K6 6 1~6 650 197 ≥27 4~10 18.5 1.1 3760
BS-K8 8 1~8 650 190 ≥20 4~10 15 1.1 6463
BS-K16 16 2~15 750 160,170 ≥27 6~15 30 1.1 9231
BS-K24 24 7~20 830 154,159 ≥29 8~-18 37 1.1 11000
BS-K38 38 10~30 910 141 ≥34 10~20 45 1.1 12677

Specifications of BSF flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of Impeller r/min Revolution of impeller Air pressure of blower  kpa Max.air flow m3/m2.min Motor power kg Weight of cell Remarks
kw For agitating kw For paddle
BSF-2.2 2.2 0.5~3 420 260 ≥15 2~3 5.5 1.1 1750 It should be arranged with gradient
BSF-4 4 0.5~4 500 230,220 ≥17 3~6 7.5 1.1 2568
BSF-6 6 1~6 650 197 ≥21 4~10 18.5 1.1 3760
BSF-8 8 1~8 650 180,190 ≥27 4~10 15 1.1 6463
BSF-16 16 2~15 750 160,170 ≥27 6~15 30 1.1 9231
BSF-24 24 7~20 830 154,159 ≥29 8~-18 37 1.1 10800
BSF-38 38 10~30 910 141 ≥34 10~20 45 1.1 12677

Specifications of JYF flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of Impeller r/min Revolution of impeller Air pressure of blower  kpa Max.air flow m3/m2.min Motor power kg Weight of cell Remarks
kw For agitating kw For paddle
JYF-1 1 0.2~1 400 358 ≥12.6 2 5.5 1.1 1154 It is aerated,and the pulp is automatically pumped. It is horizontally arranged without foam pump
JYF-2 2 0.4~2 460 331 ≥14.7 2 7.5 1.1 1659
JYF-3 3 0.6~3 540 266 ≥19.8 2 11 1.1 2259
JYF-4 4 1.2~4 620 225 ≥19.8 2 15 1.1 2669
JYF-8 8 3~8 720 199.8 ≥21.6 2 22 1.5 3868
1~8 650 190 ≥21 2 15 1.5 3854
JYF-16 16 4~16 740 160 ≥25.5 2 30/37 1.5 6520
JYF-24 24 4~24 950 153 ≥30.4 2 37 1.5 8000
JYF-38 38 10~38 ≥34.3 2 45 1.5 11000

Specifications of GF flotation cell

Model m3Effective Volume Capacity m3/min mm Diameter of Impeller r/min Revolution of impeller Motor power kg Weight of cell Remarks
kw For agitating kw For paddle
GF-1.1 1.1 0.2~0.5 400 345 5.5 1.1   Horizontally arranged without foam pump
GF-2.0 2 0.3~1.0 490 293.9 7.5 1.5  
GF-3.0 3 0.5~1.5 570 268 11 1.5  


Note: The maximum air flow reference in choosing the blower, while it is 1.0m3/m2.min for normal operation.